Seitenansicht 26
Parker Hannifin
System Configuration 27
Program/PLC Level
The "program" or “PLC” level lets you edit and run individual
programs or PLCs. The command prompt at the program level is as
follows:
Pnn>
The command prompt at the PLC level is as follows:
PLCn>
Where "nn" or “n” represents the currently active program number.
To select the program or PLC level from any other level, issue the
PROG or PLC command followed by the program number. For
example, the following selects program number 1 no matter which
level or program is active:
To go back to the system level from the program or PLC level,
issue the SYS command.
To move between programs, issue the PROG or PLC command
followed by the desired program or PLC number.
The following figure shows the various communication channel
levels. The communication channels on the left can all be active at
the same time and be operating at different levels. For example,
"COM1:" could be editing program number 3, while "COM2:"
monitors user variables being modified by program number 5.