18 Programmer’s Guide
2. The PGAIN is increased to 0.0005 to increase the response. As
Figure 2 illustrates, the motor response increased significantly,
the motor is under-damped.
Before we continue adjusting the motor response, it is
important to compensate for the under-damping by adding
DGAIN.