Installation Manual 42 Y1-03-0204 Rev.J
53
AIS: BATTERY SOON
LOW
Battery is soon out
of capacity
Reaction: Own ship data is lost after powering on/off the system.
Remedy: consider to contact Technical Support for additional help
55
AIS: PRESS ENTER TO
EXIT 1W/AUTO TX
MODE
Conditions for
enabling 1 Watt
TX power are not
valid
Reaction: Conditions for enabling 1 Watt TX power are not valid.
This means that:
the speed is >3kn and / or
the navigational status is NOT moored / at anchor and / or
the ship type is NOT “Tanker”
Remedy:
Check the conditions (SOG, Navstat, Shiptype)
if GPS is valid ( a invalid GPS causes also this alarm)
56
AIS: ENTER MMSI
NUMBER
No valid MMSI
entered.
Reaction: During the initial boot or after “factory settings” the user is
asked to enter a valid MMSI. As long as this is not done, the system
does not transmit.
Remedy: Enter a valid MMSI