User Manual 60 Y1-03-0203 Rev.L
c) Changing the MMSI / IMO Numbers
This screen provides a means to change the MMSI and IMO Numbers; the input fields are limited to
a maximum of 9 characters.
Dynamic Keys: Change MMSI / IMO
[M5]
[Save]
Save MMSI/IMO
Number Input
[Enter]
Navigate Data Input
Fields (up/down)
[M8]
[Back]
Return to Submenu
Service
Configuration
[Up] /
[Down]
Navigate Data Input
Fields (up/down)
d) Restore Factory Settings
CAUTION: By acknowledging the return to Factory Settings Command, all previous settings,
both the User and Service Passwords and all manually input data are automatically deleted!
N 1
o
19' E 0
o
13' |1>0.10|2>1.30|3>1.80nm
********** Change MMSI / IMO ***********
MMSI :1193046
IMO No.:303174162
----------------------------------------
NUM| Save | | | Back
N 1
o
20' E 0
o
13' |1>0.10|2>1.30|3>1.80nm
******* Restore Factory Settings *******
Really overwrite all settings?
Note: This also affects both passwords.
Please acknowledge with OK!
----------------------------------------
| OK | | |<-Back